Combi Boiler Problem Reset: A Comprehensive Guide

Combi boilers are a popular and efficient heating solution, providing both central heating and domestic hot water in a single compact unit. However, like any complex system, combi boilers can sometimes encounter issues that require a reset to restore normal operation. This comprehensive guide will delve into the common problems, troubleshooting steps, and the process of resetting a combi boiler, equipping you with the knowledge to handle these situations effectively.

Common Issues and Fault Codes

Rinnai Combi Boiler Troubleshooting

  1. Error Code 1P9 and Fault Code 140 (Dynamic Pressure Check Failed): This issue is specific to the Rinnai M-Series M090CN condensing combi boiler. The symptoms include no domestic hot water (DHW) and the boiler refusing to fire when the fault is active.
  2. Cause: The three-way valve might be stuck, preventing proper water flow through the DHW heat exchanger.
  3. Solution: Manually depress the three-way valve to resolve the issue and restore normal operation.

General Faults and Lockout

  1. Boiler Lockout: Boiler lockout occurs when there is a fault or safety risk within the system, causing the boiler to shut down. This can be indicated by flashing lights, error codes on the display screen, and a complete loss of hot water or heating.
  2. Causes: Lockouts can be triggered by a wide range of issues, from minor problems like frozen condensate pipes to more serious faults requiring professional attention.

Steps to Reset a Combi Boiler

Combi Boiler Problem Reset

  1. Locate the Reset Button:
  2. The reset button is typically marked with a flame or cross symbol and its location can vary depending on the boiler manufacturer and model.
  3. Refer to your boiler’s user manual to identify the exact location of the reset button.

  4. Push and Hold the Reset Button:

  5. Typically, you’ll need to hold the reset button down for 3-10 seconds, but the exact duration may differ based on the boiler model.
  6. After pressing the reset button, wait for 2-5 minutes for the boiler to restart and resume normal operation.

  7. Repeat if Necessary:

  8. If the boiler doesn’t restart after the initial reset, you can repeat the process up to three times.
  9. Avoid repeatedly pressing the reset button quickly, as this can potentially damage the control panel.

  10. Call a Professional if Needed:

  11. If the boiler still doesn’t restart after three reset attempts, it’s likely that there is a more serious fault that requires the attention of a Gas Safe registered engineer.

Manufacturer-Specific Reset Procedures

Vaillant Boilers

  • ecoTEC Plus: Press and hold the reset button for 1 second.
  • ecoFIT Pure: Press and hold the reset button for 5 seconds.

Worcester Boilers

  • CDI Classic: Press and hold the reset button for 3 seconds.
  • Greenstar i Junior: Hold the reset button for 5 seconds.

Baxi Boilers

  • EcoBlue Heat: Push and hold the reset button for 5 seconds.
  • Platinum, Platinum+, Duo-Tec: Turn the selector switch to R, hold for 5 seconds, then let it go.

Additional Tips and Resources

  • Always refer to your boiler’s user manual for the specific reset instructions, as they may vary between manufacturers and models.
  • If you’re unsure about the fault or the reset process, it’s best to consult a Gas Safe registered engineer for professional assistance.
  • For more detailed guides and troubleshooting resources, visit websites like Plumbnation, Boiler Guide, and Skills Training Group.

By following the steps outlined in this comprehensive guide and understanding the common issues and manufacturer-specific reset procedures, you’ll be well-equipped to effectively reset your combi boiler and restore its proper functionality.