How to Test MRCOOL Inverter Board: A Comprehensive DIY Guide

Summary

Testing the MRCOOL inverter board is a crucial step in troubleshooting any issues with your mini-split air conditioning system. This comprehensive guide will walk you through the step-by-step process of testing the MRCOOL inverter board, including the necessary tools, voltage checks, and potential solutions to common problems. Whether you’re a seasoned DIY enthusiast or a first-time homeowner, this guide will provide you with the technical expertise and hands-on instructions to diagnose and address any concerns with your MRCOOL inverter board.

Preparing for the Test

how to test MRCOOL inverter boardImage source: nan

Before you begin testing the MRCOOL inverter board, ensure that you have the following tools and equipment:

  1. Phillips head screwdriver: This will be used to remove the control board cover and access the inverter board.
  2. Voltmeter: A digital multimeter is essential for measuring the various voltages within the system.
  3. Notebook and pen: Keep track of your findings and measurements for reference.

Turning Off the System

  1. Locate the air handler and turn it off.
  2. Flip the breaker to the air conditioning system, and wait approximately 2 minutes for the system to reset.
  3. Turn the air handler back on.

Checking for Interference

  1. If the air handler takes 20 minutes or more to come back on, it’s likely due to an interruption in the control wire signal.
  2. Check for any potential sources of interference, such as televisions or microwaves, and turn them off.
  3. Observe if the error code appears again within 3 seconds. If so, it’s most likely a control board issue.

Verifying Wiring Connections

  1. Inspect the wiring connections between the indoor and outdoor units, ensuring that the wire numbers match the connections.
  2. If the wiring is correct but you’re still seeing the error code, proceed to the next step.

Measuring AC Voltage

  1. Use your voltmeter to check the AC voltage between L1 and L2 on the condenser.
  2. If the AC voltage is within the expected range, move on to the next step.
  3. If the AC voltage is not within the expected range, check the wiring connections and the power supply to the system.

Checking AC Voltage on Air Handler Wires

  1. Measure the AC voltage on wires 1 and 2 going to the air handler.
  2. Ensure that the voltage is within the expected range.
  3. If the voltage is not within the expected range, check the wiring connections and the control board.

Measuring DC Voltage

  1. Use your voltmeter to measure the DC voltage between terminals 2 and 3 (black lead on 2, red lead on 3).
  2. If the value is fixed and close to zero, check the wiring connection from the indoor terminal to the indoor primary control board.
  3. If the value is alternating between negative and positive, you will need to replace the indoor primary control board.

Replacing the Condenser Control Board

  1. Gently remove the cover from the top of the condenser.
  2. Locate the black control board cover on the right side.
  3. Remove the screws to access the control board.
  4. Carefully disconnect the wiring and replace the control board.
  5. Reconnect the wiring and replace the cover.

Importance of Understanding the System

When testing or replacing the MRCOOL inverter board, it’s crucial to have a clear understanding of the system’s wiring and voltage requirements. Using a voltmeter to diagnose any issues with the control board or wiring is essential, and replacing the indoor primary control board may be necessary if the DC voltage is alternating between negative and positive.

Conclusion

By following the step-by-step instructions outlined in this guide, you’ll be able to effectively test and troubleshoot the MRCOOL inverter board in your mini-split air conditioning system. Remember to always prioritize safety and consult a professional if you’re unsure about any aspect of the process. With the right tools and a methodical approach, you can confidently diagnose and address any issues with your MRCOOL inverter board.

References:

  1. How to Troubleshoot an EL 01 Error Code on 4th Gen MRCOOL DIY…
  2. IPM replacement Mr Cool, Carrier, outdoor control board P4…