Does a Remington 50 Propane Heater Have an Overtemp Switch?

The Remington 50 propane heater, model HH-18-PCH, is a popular choice for supplemental heating in homes, garages, and workshops. While it boasts impressive heating capabilities, one key safety feature it lacks is an overtemp switch. This article delves into the technical details of the Remington 50 propane heater, exploring its safety features, specifications, and the absence of an overtemp switch.

Safety Features of the Remington 50 Propane Heater

Despite the lack of an overtemp switch, the Remington 50 propane heater, model HH-18-PCH, is equipped with several other safety features to ensure safe operation:

  1. Tip Switch Shut-Off System: This feature automatically shuts off the heater if it is substantially tilted, preventing potential fire hazards or gas leaks.

  2. Oxygen Depletion Sensor (ODS): The ODS constantly monitors the oxygen content in the heated space and will shut off the heater if the oxygen level falls below 18%. This safeguard helps prevent the buildup of harmful carbon monoxide.

  3. Automatic Shut-Off: The heater is designed to automatically shut off if the pilot light is extinguished, ensuring that gas flow is stopped and preventing potential gas leaks.

  4. Thermal Cutoff: The heater is equipped with a thermal cutoff device that will shut off the gas supply if the internal temperature exceeds a predetermined safe limit.

  5. Flame Failure Device: This safety feature will shut off the gas supply if the pilot light or main burner flame is extinguished, preventing the uncontrolled release of gas.

Technical Specifications of the Remington 50 Propane Heater

does a remington 50 propane heater have an overtemp switch

The Remington 50 propane heater, model HH-18-PCH, boasts the following technical specifications:

Specification Value
Rated BTU/Hr (on HIGH) 18,000
Manifold Pressure 5 PSI – 150 PSI
Heating Area 450 Sq. Ft.
Minimum Clearances to Combustible Materials Must be maintained at all times
Size (Assembled) 15.1″ x 17.8″ x 24.2″
Weight 19.4 Lbs

It’s important to note that the minimum clearances to any combustible construction materials must be strictly adhered to for safe operation. Failure to maintain these clearances can result in fire hazards and potential property damage.

Absence of an Overtemp Switch

The Remington 50 propane heater, model HH-18-PCH, does not have a built-in overtemp switch. An overtemp switch is a safety device that would automatically shut off the heater if the internal temperature exceeds a predetermined safe limit, typically around 200°F (93°C).

The absence of an overtemp switch in the Remington 50 propane heater means that the user must be vigilant in monitoring the heater’s operation and surrounding environment to ensure safe use. Factors such as proper ventilation, maintaining clearances, and regular maintenance become even more critical to prevent potential overheating and fire hazards.

Troubleshooting and Maintenance

While the Remington 50 propane heater, model HH-18-PCH, does not have a DIY option for installing an overtemp switch, it does provide a comprehensive troubleshooting guide to address common issues. This guide covers topics such as:

  1. Checking for gas leaks
  2. Cleaning the heater’s components
  3. Replacing worn or damaged parts
  4. Adjusting the pilot light and main burner
  5. Troubleshooting error codes and malfunctions

Regular maintenance and adherence to the manufacturer’s instructions are crucial for the safe and efficient operation of the Remington 50 propane heater. Users should refer to the provided user manual and seek professional assistance if they encounter any issues that they are not comfortable addressing themselves.

Conclusion

In summary, the Remington 50 propane heater, model HH-18-PCH, does not have an overtemp switch as part of its safety features. However, it is equipped with other safety mechanisms, such as a tip switch shut-off system, an Oxygen Depletion Sensor (ODS), and various thermal cutoff devices. While the absence of an overtemp switch may be a concern for some users, the heater’s other safety features and the importance of proper maintenance and monitoring can help mitigate the risks associated with potential overheating.

It is essential for users to thoroughly review the manufacturer’s instructions, maintain the recommended clearances, and exercise caution when operating the Remington 50 propane heater to ensure a safe and enjoyable heating experience.

References

  1. Remington Heaters HH-18-PCH User Manual
  2. Remington 50 Propane Heater Overview
  3. COSTWAY Propane Heater with Overtemp Protection